Section 3 Electronic Control
3-3
TIMER BUTTON
For Delay Stop, the unit must be in the ON position.
For Delay Start, the unit must be in the OFF position.
When TIMER Mode is selected the LED will illuminate
above the button.
To adjust timer setting, tap or hold the UP arrow (^) or
DOWN arrow (v) to change the delay time by .5 hour
increments up to 10 hours, then by 1 hour increments
up to 24 hours. The control will count down the timer
remaining until start (8, 7.5, 7, etc.). The Delay Start
mode automatically selects cooling with maximum Fan
Speed. The temperature maintained will be the same
as previously set. To change the set temperature,
press “COOL” then Up or Down arrows until the desired
temperature is indicated on the display. After 5 seconds,
the control will automatically change the display back to
the hours remaining until the unit will start/stop. Turning
the unit “ON” or “OFF” at any time will cancel the Delay
Start/Stop function. The delay Start/Stop feature will
work until the unit either starts or stops. Once this has
happened then the above steps have to be repeated
again.
SLEEP MODE BUTTON
Press the SLEEP Mode button to activate this feature.
The LED will illuminate above the button. In SLEEP Mode
the selected cooling temperature will increase by 2°F 30
minutes after the mode is selected. The temperature
will then increase by another 2°F, after an additional
30 minutes. This new temperature will be maintained
for 7 hours before it returns to the originally selected
temperature. This ends the SLEEP Mode and the unit
will continue to operate as originally programmed. The
SLEEP Mode program can be cancelled at any time during
operation by pressing SLEEP Mode button.
CLEAN AIR BUTTON
Press the CLEAN AIR button to activate this feature. The
LED will illuminate above the button. When this feature
is turned ON, the electronic air purifi er is energized to
remove pollen and impurities from the air. To cancel this
feature, press the CLEAN AIR button and the LED will
turn OFF and the electronic air purifi er will shut off.
This feature can only be activated at the unit touchpad
only.
REMOTE SENSING FEATURE (on some models)
This feature is activated from the remote control only.
To activate the remote sensing feature, point the remote
control towards the unit and press the remote sensing
start button. The LIGHT on the unit control will pulse
to indicate it received the signal. The LIGHT on the
remote control will pulse each time it sends a signal.
It will continue to send this signal until the feature is
deactivated by pressing the remote sensing stop
button. If the unit does not receive the remote sensing
signal during any 3 minute interval, the unit will keep
indicating the remote sensing mode has ended. The
display on the remote control indicates the temperature
at the remote. The unit display indicates the set
temperature.
CHECK FILTER BUTTON
This feature is a reminder to clean the air fi lter for more
effi cient operation and cooling. The LED indicator will
illuminate after 250 hours of operation. To reset after
cleaning the fi lter, press the CLEAN FILTER button and
the light will go off.
FAHRENHEIT /CELSIUS
The control is capable of displaying temperature in
degrees Fahrenheit or degrees Celsius. To convert from
one to the other, press and hold the UP and DOWN
Temperature Selection Buttons at the same time for 3
seconds.
FAULT CODES
If the display reads “ES” or “AS” a sensor has failed.
The “ES” is for the evaporator thermistor and the “AS” is
the ambient thermistor located in the remote control.