INSTRUCTIONS MANUAL
SPLIT TYPE ROOM AIR CONDITIONER
MODELS:
Please read this manual completely before operating your room air conditioner.
110823P
S(351-358)EM_ENGLISH
EAS(C,E)09C2ASK(W,S,M) / EAS(C,E)12C2ASK(W,S,M)
EAS(C,E)18C2ASK(W,S,M) / EAS(C,E)24C2ASK(W,S,M)
EAS(C,E)09P5ASK(W,S,M) / EAS(C,E)12P5ASK(W,S,M)
EAS(C,E)18P5ASK(W,S,M) / EAS(C,E)24P5ASK(W,S,M)
Zobrazit stránku 0
1 2 3 4 5 6 ... 27 28

Shrnutí obsahu

Strany 1 - INSTRUCTIONS MANUAL

INSTRUCTIONS MANUALSPLIT TYPE ROOM AIR CONDITIONERMODELS:Please read this manual completely before operating your room air conditioner.110823PS(351-3

Strany 2 - Contents

Settlement of outdoor unitAnchor the outdoor unit witha bolt and nut 10 or 8 tightlyand horizontally on a concreteor rigid mount.MODELA (mm) B (mm)Dra

Strany 3 - Safety precautions

4. Flaring workA) Firmly hold copper pipe in a die in the dimension shown in the table below.1,31,61,82,4Máx.0,71,01,02,2A (mm)Mín.OUTERDIAMETER (mm)6

Strany 4

1. The inside and outside connecting cable can be connected without removing the front grille.2. Connecting cable between indoor unit and outdoor un

Strany 5

1. Remove the electrical control board cover from the outdoor unit by loosening the screw.2. Connect the cables to the terminals as identified with

Strany 6 - Parts list

1. Never fail to have an individual power circuit specifically for the air conditioner. As for the method of wiring, be guided by the circuit diagram

Strany 7 - Indoor unit installation

When using the vacuum pumpFor method of using a manifold valve, refer to its operation manual.1. Completely tighten the flare nuts, A, B, C, D, conne

Strany 8 - Outdoor unit

Operation testPerform test operation after completing gas leak check at the flare nutconnections and electrical safety check.1. Connect the power, pr

Strany 9 - Outdoor unit installation

Product descriptionAir outletAir inletOutdoor unitAll the pictures in this manual are for explanation purpose only. They may be slightly different fro

Strany 10 - Refrigerant pipe connection

Remote controlRemote control battery To use the remote control, it is necessary to install two (R03/Ir03x2) alkaline AAA batteries. 1. The air condit

Strany 11 - Electrical work

ON/OFF: Push this button to start operation, push the button again to stop operation.MODE: Each time you push the button, a mode is selected in a sequ

Strany 12 - 21 electrolux electrical work

Thank you for choosing Electrolux. This manual contains all of the information required to guarantee your safety and the appropriate use of your air c

Strany 13

CANCEL: Push this button to cancel the TIMER ON/OFF settings.TURBO*: Push this button on COOL mode, the air conditioner goes into powerful cooling ope

Strany 14 - Air purging

Clock adjustmentBefore you start operating the air conditioner, set the clock of the remote controller using the procedures given in this section. The

Strany 15 - Gas leak check

Air flow direction adjustmentUse SWING to adjust the airflow direction up and down.1. When swing is pressed the horizontal louver moves up and down a

Strany 16 - Operation test

seconds after, the adjusted temperature will be displayed.5. The time of on and off in the air conditioner is has been set.CancelingCancel button (CAN

Strany 17 - Product description

Press the SWING button on the remote controller.To stop the function, press the SWING button again.Press AIR DIRECTION button to lock louver in desire

Strany 18 - Remote control

MaintenanceCleaning the indoor unit and remote controller1. It is necessary to stop the air conditioner and disconnect the power supply before cleani

Strany 19 - Remote control description

Operation tipsThe following events may occur during normal operation.Protection of the air conditioner.Compressor protectionThe compressor can't

Strany 20 - LCD display indicators

Solutions for problemsPoor Equipment performance 1. The air outlet or inlet in the exterior part is obstructed.2. The temperature in the exterior is

Strany 21 - How the air conditioner works

53 electrolux technical specificationsHEAT & COOL MODELSnotes electrolux 54NOTESOUTDOOR UNITINDOOR UNIT*Color (W=White;S=Silver;M=Mirror)CycleCoo

Strany 22 - SLEEP FUNCTION (Heating mode)

6.7 How the air conditioner works...40- Automatic operation- Cool/Heat and Fan only operatio

Strany 23 - How to use the indoor unit

conditioner. It contains contaminants and could make you sick.10.Do not use the power cord close to heating appliances. It may cause fire and electric

Strany 24 - Auto/Cool

there is concern of damage due to falling of unit.28.Always insert the filters securely. Clean filter once every two weeks. Operation without filters

Strany 25 - Maintenance

121Remote controllerSelf-tapping screw B ST2.9x10Remote controller holder789Outdoor Unit1. The outdoor unit must be installed at a convenient site th

Strany 26 - Operation tips

1. This illustration is for explanation purposes only.2. Copper lines must be insulated independently754231Indoor unitOutdoorunit66More than 12cmMor

Strany 27 - INDOOR UNIT

Fixing the installation plateDrilling the Hole1. Install the installation plate horizontally over the structural parts on the wall using the spaces i

Strany 28

Piping and wrapping1. Bundle the tubing, connecting cable, and drain hose with tape securely, evenly as shown.2. Because the condensed water from re