AB
min. 20
10
20
A
5. Use at least 2 screws to fix the oven on
both sides (Detail A).
Warning! When installing next to a
wood-fuelled boiler, a heatproof and
heat-insulating plate must be mounted
at the height of the appliance and at
least 30 cm deep.
Electrical connection
Use a power cable of H05VV-F or higher.
Connect the appliance to a socket supply
line. If there is no socket supply line, the
electrical installation must have an isolation
device which lets you disconnect the appli-
ance from the power supply. The isolation
device must have a contact opening width
of minimum 3 mm (in reference to NIN SEV
1000). The customer must have a socket
for the electrical connection that is accessi-
ble and outside the coordination room. The
length of the connection cable must be ap-
proximately 120 cm with lines connected
directly to the power supply.
D
E
F
Important! Only a qualified person can
connect the appliance to the electricity
supply.
1.
Open the mains terminal cover (D).
2. Put the connection cable into the sup-
plied rings (E). This is to prevent the
cable from rubbing against the drawer.
The connection cable is on the housing
side.
3.
Install the cable grip (F).
4.
Connect the terminal as in the illustra-
tion.
5.
Put the cable into the strain relief
clamp.
6.
Close the mains terminal cover.
Connection diagram 400 V
Phase definitions: L1, L2, L3 (or R, S,T)
Warning! If service is required always
disconnect the appliance from the
power supply.
ENVIRONMENT CONCERNS
Recycle the materials with the symbol .
Put the packaging in applicable containers
to recycle it.
Help protect the environment and human
health and to recycle waste of electrical and
electronic appliances. Do not dispose
22