Flaring work
Main cause for refrigerant leakage is
due to defect in the flaring work.
Carry out correct flaring work using
the following procedure:
1. Cut the pipes and the cable.
A) Use the piping kit accessory or
pipes purchased locally.
B) Measure the distance between the
indoor and the outdoor unit.
C) Cut the pipes a little longer than
the measured distance.
D) Cut the cable 1.5m longer than the
pipe length.
2. Burr removal
A) Completely remove all burrs from
the cut cross section of pipe/tube.
B) Put the end of the copper
tube/pipe in a downward direction as
you remove burrs in order to avoid
dropping burrs into the tubing.
3. Putting nut on
A) Remove flare nuts attached to
indoor and outdoor unit, then put
them on pipe/tube having completed
burr removal.(not possible to put them
on after flaring work)
Refrigerant pipe connection
refrigerant pipe connection electrolux 18
Pipe
Correct
Wrong
Oblique Roughness Burr
Pipe
Reamer
Point
down
Flare nut
Cooper tube
37 electrolux remote control description
timed setting in 30 minutes
increments. When the setting time
displays 10:00, each press will
increase the auto-timed setting 60
minutes increments. To cancel the
auto-timed program, simply adjust
the auto-off time to 0:00.
LOCK: When you press the
recessed LOCK button, all current
settings are locked in and the
remote controller does not accept
any operation except that of the
LOCK. Press again to cancel the
LOCK mode.
TURBO*: Push this button to
activate/cancel the Turbo function
which enables the unit to reach
the preset temperature in the
shortest time.On cooling mode,
the unit w ill b low s trong co oling
air with super high fan speed. On
heating mode (applicable to the
unit adopts PTC only), the PTC
will bring fast heating operation.
*Only for some models