Fixing the installation plate
Drilling the Hole
1. Install the installation plate
horizontally over the structural
parts on the wall using the spaces
indicated on the plate, as shown in
the figure above.
2. In the case of tiled, concrete or
similar walls, create 5 mm-
diameter holes. Place anchorage
supports for the appropriate
assembly screws.
3. If expansion screws are used, the
holes must measure 11x20 or
11x26, with a distance of 450 mm
between each.
4. Fix the installation plate to the wall.
1. Determine the position of the hole
for the pipe using the installation
plate and drill the pipe hole (ø
65mm) so that it is titled slightly
downward.
2. Always use a pipe cover with an
opening when drilling a metal bar.
Installation plate
Fit the Installation Plate and drill holes
in the wall according to the wall
structure and corresponding mounting
points on the installation plate
(Dimensions are in “mm” unless
otherwise stated).
Wall
Indoor unit
Outdoor unit
5-7mm
13 electrolux indoor unit installation
24k Btu models
A type
24k Btu models
B type
how the air conditioner works electrolux 42
TIMER Operation
TIMER button can set the auto-on time of the unit.
To set the starting time
1. Push the TIMER ON button, then the remote controller shows TIMER ON ,
the last set time for the starting operation and the signal "h" will be shown on
the DIGITAL DISPLAY area. You are now ready to reset the time to START the
operation.
2. Push the TIMER ON button again to set desired unit start time.
3. After setting the TIMER ON ,there will be a one-half second delay before the
remote controller transmits the signal to the air conditioner. Then, after
approximately another 2 seconds, the signal "h" disappears and the set
temperature will re-appear on the digital display.
To set the stopping time
1. Push the TIMER OFF button and the remote controller will show TIMER OFF,
the last set time for the stopping operation and the signal "h" will be shown
on the DIGITAL DISPLAY area. You are now ready to reset the time of the
STOP operation.
2. Push the TIMER OFF button again to set the time you want to stop the
operation.
3. After setting the TIMER OFF ,there will be a one-half second delay before
the remote controller transmits the signal to the air conditioner. Then, after
approximately another 2 seconds, the signal "h" disappears and the set
temperature will re-appear on the digital display.
Exemples:
6h
(Temp On)
OFF
ON
6h
(Temp Off)
ON
OFF
12h
(Temp Off)
ON
OFF
ON
14h
(Temp On)
20h
(Temp On)
ONN
OFF
23h
(Temp Off)
OFF