3.2 Safety cutoff
Cooking field: - If you do not set a cooking level in a cook zone within approx. 10 seconds
after switching on of the cook field, the cook field switches off
automatically.
- If one or more sensor fields are covered longer than 10 seconds, e.g. by
a pot placed on it, a signal sounds and the cook field switches off
automatically.
- If all cook zones are switched off, the cook field switches off
automatically approximately 10 seconds later.
Control panel: Humidity (e.g. a wet cloth) or over-cooking liquid on the control panel switches all
cook zones off immediately.
Induction cooking zones: - During overheating (e.g. an empty-cooked pot) the cook zone switches
off automatically. „- “is displayed. Before renewed use the cook zone
must be set to „0 “and be cooled down.
- If suitable table-ware is used, „F“ flashes in the display and after 10
minutes the display of the cook zone switches off.
- If one of the cook zones is not switched off after a certain time or if the
cook stage is not changed, the appropriate cook zone switches off
automatically.
cooking level The cooking zones are disconnected with:
1-2 6 Hours
3-4 5 Hours
5 4 Hours
6-9 1,5 Hours