13electrolux gas cooktops testingtheappliance
Afterinstallation,testtheapplianceandensurethatit
operatescorrectlybeforehandingitovertothecustomer.
Thefollowingprocedureisrecommended:
1. Turnonthegasandelectricitysupplyandattempt
ignitiononallburners,bothseparatelyandin
combination.(Forcorrectprocedurerefertopage3
LightingBurners).Notethatadditionaltimeneedsto
beallowedfortheinitiallightingasairhastobepurged
fromthepipes.
2. Observetheflameappearanceoneachburner
(Figure11).Ifitismuchlargerormuchsmallerthan
expected,theinjectorsizeandsupplypressurerequire
checking.Whereaflameisunsatisfactory,refertothe
TroubleshootingGuide(page5)tocorrectthefault.If
theTroubleshootingGuidedoesnotsolvetheproblem,
calltheServiceCentre.
3. Whenalltheforegoingissatisfactory,checkthe
turndown(minimumorlow)settingoneachburner,
asthismayneedadjustment.Valveshaveabypass
controllingscrew,whichmaybeaccessedbyremoving
theknob.Thisscrewwillbelocatedonaparticulararea
ofthevalve(referFigure12).Normally,thiswillhave
beencorrectlysetatthefactoryforuseonNaturalGas
(NG)andshouldnotrequireadjustment.
IftheappliancehasbeenconvertedtoLPG,thenthe
bypassscrewwillHAVE tobescrewedinuntilasmall,
stableflameresults.
Please ensure the supply pressure has been
checked PRIOR to any adjustment.
4. Iftheappliancecannotbeadjustedtoperformsafely
informthecustomeroftheproblemandaffixan
appropriatewarningnoticetotheappliance.Ifthefault
appearstobedangeroustheapplianceshouldbe
disconnected.Ifaminorfaultexists,thecustomermay
wishtousetheappliancewhileawaitingservice.
Ifafaultcannotbefixed,pleasecalltheServiceCentre.
5. Thecustomershouldbeadvisedthat,intheevent
ofafault,thelocalserviceorganisationortheretailer
fromwhomtheappliancewaspurchasedshouldbe
contacted.
6. Whensatisfiedthattheunitisoperatingcorrectly,turn
offandinstructthecustomeroncorrectoperationas
outlinedinthisbooklet.Askthecustomertooperate
thecontrolstoensurethatthecorrectprocedureis
understood.
Testingapplianceoperation
Flamesizeadjustedtomaximum
Flamesizeadjustedtominimum
Bypassscrew
Figure11
Figure12
Servicing must only be carried out by an authorised
service person.
Injectorsizesrequiredforvariousgastypesareshownin
Table3(page10).Theappliancetestpointpressurefor
eachgastypeisalsoshown.
Formodelidentificationafterinstallation,anadditionaldata
platestickerhasbeenprovided.Thisstickeristobestuck
ontoadjacentcabinetry.
Komentáře k této Příručce