9electrolux gas cooktops gasconnection
Gas connection
This appliance is supplied for use with Natural Gas.
However, it can be converted for use with LPG. Refer
to LP conversion on page 10.
Supply pipe sizing
Thetotalhourlygasconsumptionfortheapplianceis
shownonthedatalabel.Therequiredsupplypressure
(i.e.atinlettoapplianceregulator)foreachgastypeis
shownonthedatalabel,andgiveninTable3(page10).
Usethisinformationinconjunctionwiththelengthofrun,
numberofelbows,teesandbends,theavailableservice
pressureandthesupplyrequirementsofotherinstalled
appliancestodetermineasuitablepipesize.
Forassistanceinthismatterrefertotheappropriate
sectionoftheInstallationCodeAS5601.
AnAGAcertifiedclassBorDflexibleconnectionmay
beusedtoconnectthecooktopinaccordancewith
theAS5601andinparticularsection4.8.Whereahose
assemblyisusedandthecooktopisintheinstalled
position,thehoseassemblyshallbesuitableforconnection
toafixedconsumerpipingoutletlocatedatapoint
800–850mmabovethefloorandintheregionoutside
thewidthoftheappliancetoadistanceof250mm.The
pointofconnectiontoconsumerpipingmustbeaccessible
withapplianceinstalled.
Elbow positioning
Itispossibletorepositiontheelbowifrequiredby
looseningthelockingnutandelbowbyusingtwo
spanners.Re-tightentheentireassemblyaftertheelbow
hasbeenrepositioned.Whenfittingelbowtoappliance,
ensurethatthesealingwasherisfitted.
Regulator
Anapplianceregulatorisprovided.Theregulatormustbe
positionedsothatthepressuretestnippleisaccessible
whentheapplianceisinstalled.
Connectthegassupplytothe½”B.S.P.internalthread
inletoftheregulator.Referto‘benchcutout’(Figure6)for
connectionpointposition.
Regulatorsaresuppliedpre-adjustedandconfiguredbythe
componentmakerforusewithNaturalGas.
Theapplianceinstallerisnotrequiredtomakean
adjustmenttoobtainthecorrectoutletpressuresetting.
Anarrowonthebaseoftheregulatorindicatesthe
directionofgasflowwhentheinletandoutletofthe
regulatorisorientatedcorrectly.Whentheregulatorhas
beenfittedcheckforleaksfromtheconnectionswith
soapywater.
OperationonN.G./S.N.G. OperationonN.G./S.N.G.
Assembly of Regulator
Theassemblyoftheregulatortothecooktopmanifoldis
achievedviatheelbowunionandsealingwashersupplied,
refertofigure9.
The½”parallelthreadconnectstothemanifold,andthe
sealingwasherisplacedbetweenthemanifoldendand
theflatfaceontheelbow.
The½”taperedthreadconnectstotheoutletofthe
regulator,andissealedonthethreadusingapproved
threadsealingtapeorapprovedthreadsealingcompound.
Theinletoftheregulatorisa½”parallelthreadand
isconnectedtoconsumerpipingorhoseassembly.
Regulatorsaresuppliedpre-adjustedandconfigured
bythecomponentmakerforusewithNaturalGas.
Theapplianceinstallerisnotrequiredtomakean
adjustmenttoobtainthecorrectoutletpressuresetting.
Anarrowonthebaseoftheregulatorindicatesthedirection
ofgasflowwhentheinletandoutletoftheregulatoris
orientatedcorrectly.Whentheregulatorhasbeenfitted
checkforleaksfromtheconnectionswithsoapywater.
Figure9
½”Taperedthread
Sealusingapproved
sealingtapeor
approvedthread
sealingcompound
Manifold
endform
Femalenut Flatface
Sealing
washer
½”Parallel
thread
Regulator
Outlet
Inlet