A. Rigid copper pipe or flexible pipe of
stainless steel
3.6 Connection cable
To replace the connection cable use only
the special cable or its equivalent. The
cable type is: H05V2V2-FT90.
Make sure that the cable section is
applicable to the voltage and the working
temperature. The yellow / green earth
wire must be approximately 2 cm longer
than the brown (or black) phase wire.
3.7 Building In
30 mm
55 mm
40-50 mm
min. 650 mm
490 mm
min. 450 mm
270 mm
A. supplied seal
B. supplied brackets
CAUTION!
Install the appliance only on
a worktop with flat surface.
3.8 Installation of more than
one hob
If several hobs are to be installed side by
side into the same cut out, an assembly
kit including a support side bracket and
supplementary seals is available at our
Authorised Service Centres. The relevant
installation instructions are supplied
within the kit package.
3.9 Installing hob under the
hood
If you install the hob under a
hood, please see the
installation instructions of the
hood for the minimum
distance between the
appliances.
3.10 Possibilities for insertion
The panel installed below the hob must
be easy to remove and let an easy
access in case a technical assistance
intervention is necessary.
Kitchen unit with door
min 30 mm
60 mm
B
A
min 20 mm
(max 150 mm)
A. Removable panel
B. Space for connections
ENGLISH 9