1 Safety Instructions for
the Installer
A device must be provided in the electrical installa-
tion which allows the appliance to be disconnected
from the mains at all poles with a contact opening
width of at least 3 mm.
Suitable isolation devices include line protecting
cut-outs, fuses (screw type fuses are to be re-
moved from the holder), earth leakage trips and
contactors.
In respect of fire protection, this appliance corre-
sponds to EN 60 335-2-6. This type of appliance
may be installed with a high cupboard or wall on
one side.
Drawers may not be fitted underneath the hob.
The installation must guarantee shock protection.
The kitchen unit in which the appliance is fitted
must satisfy the stability requirements of
DIN 68930.
For protection against moisture, all cut surfaces
are to be sealed with a suitable sealant.
On tiled work surfaces, the joints in the area where
the hob sits must be completely filled with grout.
On natural, artificial stone, or ceramic tops, the
snap action springs must be bonded in place with
a suitable artificial resin or mixed adhesive.
Ensure that the seal is correctly seated in the frame
and that it is seated against the work surface with-
out leaving any gaps. Additional silicon sealant
must not be applied; this will make removal more
difficult when servicing.
The hob must be pressed out from below when re-
moved.
Clean the worktop around the cut-out area.
Attach the supplied one-sided adhesive liner tape
around the cut-out on the top surface of the work-
top. The joining point of the two ends should be in
the middle of one of the sides. After cutting the
correct length (allow a few millimetres) simply
press the two ends against each other.
For Australia:
CAUTION: The surface temperature exceeds 95°C.
To avoid a hazard, underbench access must be re-
stricted.
Supply cords must have a temperature rating not
less than 105°C.