9.3 Other technical data
TOTAL POW‐
ER:
Gas original: G20 (2H) 20 mbar 3,7 kW
Gas replace‐
ment:
G30/G31 (3B/P) 30/30 mbar 276 g/h
Electric sup‐
ply:
220-240 V ~ 50/60 Hz
Appliance cat‐
egory:
II2H3B/P
Gas connec‐
tion:
G 1/2"
Appliance
class:
3
9.4 Gas burners for NATURAL GAS G20 20 mbar
BURNER NORMAL POWER
kW
MINIMUM POWER
kW
INJECTOR MARK
1/100 mm
Triple Crown 3,7 1,4 135
9.5 Gas burners for LPG G30/G31 30/30 mbar
BURNER NORMAL
POWER kW
MINIMUM
POWER kW
INJECTOR
MARK
NOMINAL GAS
FLOW g/h
Triple Crown 3,8 1,4 98 276
10. ENERGY EFFICIENCY
10.1 Product information according to EU 66/2014
Model identification EGC3313NVK
Type of hob Built-in hob
Number of gas burners 1
Energy efficiency per gas burner
(EE gas burner)
Centre middle - Triple Crown 55.1%
Energy efficiency for the gas hob
(EE gas hob)
55.1%
EN 30-2-1: Domestic cooking appliances burning gas - Part 2-1 : Rational use of
energy - General
10.2 Energy saving
• Before use, make sure that the burners and pan supports are assembled correctly.
• Use cookware with diameters applicable to the size of burners.
www.electrolux.com16